TAKERU™ PTCA Balloon Dilatation Catheter
- RX Semi-compliant
- RX Non-compliant
- Over the Wire options
SUPERIOR FLEXIBILITY
Superior tracking through tortuous anatomy1
SUPERIOR PUSHABILITY
Unsurpassed pushability vs. leading PTCA balloon catheters1
LOWER PROFILE FOR CROSSABILITY
Engineered for optimized performance in reaching and crossing complex lesions2-4
RX TAKERU PTCA DILATATION CATHETER
- 1.5mm balloon with a lower entry profile than the leading 1.2mm balloon to help cross complex lesions1,2
- Greater tip flexibility allows Takeru to go further through tortuous anatomy1
- Tightest re-wrap to support re-crossability within the same procedure1
RX NC TAKERU
High pressure balloon ideal for post dilatation after stent placement
- Superior pushability to help cross tortuous anatomy1
- Tightest re-wrap compared to leading competitors1
PRODUCT ANIMATION
PRODUCT CODES
NC Takeru Codes
| BALLOON DIAMETER (MM) |
BALLOON LENGTH (MM) | |||
| 8 | 12 | 15 | 21 | |
| 2.00 | DC-RZ2008UA2 | DC-RZ2012UA2 | DC-RZ2015UA2 | DC-RZ2021UA2 |
| 2.25 | DC-RZ2208UA2 | DC-RZ2212UA2 | DC-RZ2215UA2 | DC-RZ2221UA2 |
| 2.50 | DC-RZ2508UA2 | DC-RZ2512UA2 | DC-RZ2515UA2 | DC-RZ2521UA2 |
| 2.75 | DC-RZ2708UA2 | DC-RZ2712UA2 | DC-RZ2715UA2 | DC-RZ2721UA2 |
| 3.00 | DC-RZ3008UA2 | DC-RZ3012UA2 | DC-RZ3015UA2 | DC-RZ3021UA2 |
| 3.25 | DC-RZ3208UA2 | DC-RZ3212UA2 | DC-RZ3215UA2 | DC-RZ3221UA2 |
| 3.50 | DC-RZ3508UA2 | DC-RZ3512UA2 | DC-RZ3515UA2 | DC-RZ3521UA2 |
| 4.00 | DC-RZ4008UA2 | DC-RZ4012UA2 | DC-RZ4015UA2 | DC-RZ4021UA2 |
Over the Wire Takeru Codes
| Balloon Diameter (mm) | Balloon Lengh (mm) | ||||
| 6 |
8 | 12 | 15 | 20 | |
| 1.50 | DC-PY1506UA1 | DC-PY1512UA1 | DC-PY1515UA1 | DC-PY1520UA1 | |
| 2.00 | DC-PY2008UA2 | DC-PY2012UA2 | DC-PY2015UA2 | DC-PY2020UA2 | |
| 2.25 | DC-PY2212UA2 | DC-PY2215UA2 | DC-PY2220UA2 | ||
| 2.50 | DC-PY2508UA2 | DC-PY2512UA2 | DC-PY2515UA2 | DC-PY2520UA2 | |
| 3.00 | DC-PY3008UA2 | DC-PY3012UA2 | DC-PY3015UA2 | DC-PY3020UA2 | |
| 3.50 | DC-PY3508UA2 | DC-PY3512UA2 | DC-PY3515UA2 | DC-PY3520UA2 | |
| 4.00 | DC-PY4008UA2 | DC-PY4012UA2 | DC-PY4015UA2 | DC-PY4020UA2 | |
RX Takeru Codes
| BALLOON DIAMETER (MM) | BALLOON LENGTH (MM) | ||||
| 6 | 8 | 12 | 15 | 20 | |
| 1.50 | DC-RY1506UA1 | DC-RY1512UA1 | DC-RY1515UA1 | DC-RY1520UA1 | |
| 2.00 | DC-RY2008UA2 | DC-RY2012UA2 | DC-RY2015UA2 | DC-RY2020UA2 | |
| 2.25 | DC-RY2212UA2 | DC-RY2215UA2 | DC-RY2220UA2 | ||
| 2.50 | DC-RY2508UA2 | DC-RY2512UA2 | DC-RY2515UA2 | DC-RY2520UA2 | |
| 3.00 | DC-RY3008UA2 | DC-RY3012UA2 | DC-RY3015UA2 | DC-RY3020UA2 | |
| 3.50 | DC-RY3508UA2 | DC-RY3512UA2 | DC-RY3515UA2 | DC-RY3520UA2 | |
| 4.00 | DC-RY4008UA2 | DC-RY4012UA2 | DC-RY4015UA2 | DC-RY4020UA2 | |
DOCUMENTS
ASSOCIATED PRODUCTS
REFERENCES
RX ONLY. Refer to the product labels and package insert for complete warnings, precautions, potential complications, and instructions for use.
1. Data on file.
2. RX NC Takeru, 2022.
3. RX Takeru IFU, 2022.
4. OTW Takeru IFU, 2020.